2,521
edits
Lars Krause (talk | contribs) |
Lars Krause (talk | contribs) |
||
Line 69: | Line 69: | ||
|- | |- | ||
| [[Hydrothermal processing#Lule.C3.A5 University of Technology LTU|Luleå University of Technology LTU]] | | [[Hydrothermal processing#Lule.C3.A5 University of Technology LTU|Luleå University of Technology LTU]] | ||
| | | Sweden | ||
| | | - | ||
| | | Organosolv pre-treatment | ||
| | | 6-7 | ||
| | | - | ||
| | |30 | ||
| | |230 | ||
| | |Continuous organosolv reactor | ||
| | | - | ||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |●X | |||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |●X | |||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
|- | |- | ||
| [[Hydrothermal processing#Montinutra OY|Montinutra OY]] | | [[Hydrothermal processing#Montinutra OY|Montinutra OY]] | ||
| | | Finland | ||
| | | - | ||
| | | Hydrothermal processing, pressured hot water extraction | ||
| | | 7 | ||
| 0.11 | |||
| | | - | ||
| | |150-200 | ||
| | | - | ||
| | | - | ||
| | |||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |●X | |||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
| class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | | class="cd-background-lightgreen cd-text-darkgreen" style="text-align:center" |● | ||
Line 101: | Line 101: | ||
|- | |- | ||
|[[Hydrothermal processing#SCF Technologies A.2FS|SCF Technologies A/S]] | |[[Hydrothermal processing#SCF Technologies A.2FS|SCF Technologies A/S]] | ||
|Denmark | |||
| - | |||
|CatLiq | |||
|6-7 | |||
|15000 | |||
|250 | |||
|>400 | |||
| - | |||
| - | |||
|X | |||
|X | |||
| | | | ||
| | |X | ||
| | | | ||
|- | |- | ||
|[[Hydrothermal processing#TerraNova Energy GmbH|TerraNova Energy GmbH]] | |[[Hydrothermal processing#TerraNova Energy GmbH|TerraNova Energy GmbH]] | ||
| | |Germany | ||
| | | - | ||
| | |TerraNova ultra | ||
| | |8-9 | ||
| | | - | ||
| | |20-35 | ||
| | |180-200 | ||
| | |Hydrothermal carbonization | ||
| | | - | ||
| | |X | ||
| | |X | ||
| | |X | ||
| | | | ||
| | | |